The Model FT3 was designed with our oil and gas customers in mind. This meter is Quad O (OOOO) compliant and is perfect for use in flare gas applications along with other fuel gas measurement.
Key Features:
Applications:
The free FT3 View™ software from Fox Thermal is a great way to access the meter settings directly by connecting the FT3 to a PC or laptop using a USB cable. View or change the meter settings with a simple click of the mouse. The FT3 software offers:
Note: For FT3 View™ software to function properly, please be sure to have a working version of Microsoft® Office installed on the PC before installing FT3 View™.
USB Driver and the Fox Thermal FT3 View™ Software
A USB driver is needed for FT3 View™ to run. If the USB drive does not install automatically, you will need to download it by following this link. Instructions are included on how to install it correctly.
The CAL-V™ and Zero CAL-CHECK® tests are used for Calibration Validation on the Model FT3. These tests do the following:
Use this test according to the manufacturer’s instructions in order to validate the calibration of the meter.
Flow meter accuracy is often dependent on achieving a uniform flow profile near the center of the pipe. Distortion and swirl are disturbances in flow that can be remedied either by extending the length of space between the cause of the disturbance and the sensing element (increasing straight pipe runs) or by adding a flow conditioner to correct the disturbance. Flow conditioners installed upstream of flow meters reduce the need for long, straight pipe runs. Common Features for Fox Thermal FC20 Flow Conditioner:
More Info
Technical Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fox Thermal Model FT3 Thermal Mass Flow Meter & Temperature Transmitter | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Performance Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Accuracy: | ± 1% of reading ± 0.2% of full scale. 15 diameters of straight, unobstructed pipe upstream and 10 downstream. |
± 1% of reading ± 0.2% of full scale. 8 diameters of straight, unobstructed pipe upstream and 4 downstream. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Repeatability: | ± 0.2% of full scale | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Response Time: | 0.9 seconds (one time constant) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature Accuracy: | ± 1.8°F (± 1.0°C) -40 to 250°F (-40 to 121°C); ± 3.6°F (± 2.0°C), 250 to 650°F (121 to 343°C); 60 SFPM minimum. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Calibration: | Factory Calibration to NIST-traceable standards CAL-V™ and Zero CAL-CHECK®: In situ, operator-initiated calibration validation |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Units (field selectable): | SCFM, SCFH, NMPS, NM3/M, NM3/H, NM3/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMSCFM, SMPS, SM3/H, LB/S, LB/M, LB/H, LB/D, KG/S, KG/M, KG/H, SLPM, SFPM, MT/H, SM3/M | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Rates: | 15 to 60,000 SFPM (0.07 to 280 NMPS) - Air at 70°F (20°C) & 1 ATM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Turndown: | up to 1000:1; 100:1 typical | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Ranges: |
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note: Standard conditions of air at 70°F and one atmosphere. Consult factory for other gases, pipe sizes, and flow ranges other than those listed. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Gas Pressure (max): | 500 psig (34.5 barg) |
316 SS inline w/NPT ends: 500 psig (34.5 barg) 316 SS inline w/150lb flanges: 230 psig (16 barg) CS inline w/NPT ends: 500 psig (34.5 barg) CS inline w/150lb flanges: 285 psig (20 barg) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Check with factory for higher pressure options. Note: Pressure ratings stated for temperature of 100°F (38°C). |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Relative Humidity: | 90% RH maximum; non-condensing | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature by Sensor Type: (see Approvals tab) | ST Sensor: -40 to 250°F (-40 to 121°C) HT Sensor: -40 to 650°F (-40 to 343°C) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature by Enclosure: (see Approvals tab) | Without display or AC power supply: -40 to 158°F (-40 to 70°C) With display and/or AC power supply: -4 to 158°F (-20 to 70°C) Remote sensor junction box: -40 to 212°F (-40 to 100°C) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Power: |
Note: Fluctuations of AC and DC power supply are not to exceed ±10% of rating.
Class I Equipment (Electrical Grounding Required for Safety). Installation (Over-voltage) Category II for transient over-voltages. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inputs/Outputs: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Port: | Mini USB communication port is standard. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Software: | The free PC-based software tool - FT3 View™ - provides complete configuration, remote process monitoring, and data logging functions. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Optional serial communication: | HART or Modbus RTU (RS485). | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4-20mA Loop Verification: | Simulation mode used to align 4-20mA output with the input to customer’s PLC/DCS. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Physical Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sensor Material: | 316 stainless steel standard. Hastelloy C276 optional. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure: | NEMA 4X (IP68), Aluminum, dual conduit entries with ¾" NPT or optional M20 x 1.5mm. Cabling to remote enclosure: 5-conductor, 18 AWG, twisted, shielded, 100 feet maximum. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Retractor Assemblies: | Packing gland assembly: 125 psig (8.6 barg ) max. High pressure (crank) retractor: NPT 600 psig (41.4 barg), ANSI 150 flange & ANSI 300 flange, no valve supplied. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Installation: | Fox Thermal-supplied compression fitting connects to customer-supplied ¾" female coupling welded to pipe. | Compression fitting included with flow body. |
CE: Approved
FM and FMc: Approved
ATEX (FM12ATEX0034X): Approved
IECEx (IECEx FMG 12.0010X): Approved
ATEX and IECEx Standards:
Model Code | Temperature Code Marking (Gas) | Temperature Code Marking (Dust) | |||
---|---|---|---|---|---|
Enclosure | Sensor Type | Main Enclosure | Remote Enclosure | Main Enclosure | Remote Enclosure** |
E1 | ST | T4 | N/A | 135°C | N/A |
E2 | ST | T4 | N/A | 135°C | N/A |
E3 | ST | T6 | T4 | 85°C | 135°C** |
E4 | ST | T6 | T4 | 85°C | 135°C** |
E3 | HT | T6 | T1 | 85°C | 450°C** |
E4 | HT | T6 | T1 | 85°C | 450°C** |
*Temperature code ratings for Zones are dependent on external process temperature factors and equipment enclosure configuration. See the table above for specific temperature code ratings.
**The IECEx dust rating does not apply to the Remote Enclosure.
Model Code | Temperature Code Marking (Gas) | Temperature Code Marking (Dust) | |||
---|---|---|---|---|---|
Enclosure | Sensor Type | Main Enclosure | Remote Enclosure | Main Enclosure | Remote Enclosure** |
E1 | ST | T4 | N/A | 135°C | N/A |
E2 | ST | T6 | N/A | 135°C | N/A |
E3 | ST | T6 | T4 | 85°C | 135°C** |
E4 | ST | T4 | T4 | 85°C | 135°C** |
E3 | HT | T6 | T1 | 85°C | 450°C** |
E4 | HT | T6 | T1 | 85°C | 450°C** |
*Temperature code ratings for Zones are dependent on external process temperature factors and equipment enclosure configuration. See the table above for specific temperature code ratings.
**The IECEx dust rating does not apply to the Remote Enclosure.
Talk with our application specialist or a rep near you for sizing and materials requirements
Model FT3 View™ Information to View and/or Download | |
---|---|
FT3 View™ Software | |
FT3 View™ Datasheet | |
FT3 View™ Manual | |
VCP Driver (for FT3 View™ Software) |
Note regarding VCP Driver: If the PC is connected to the Internet and running Windows® 7, 8, or 10, the PC will try to automatically load the VCP driver. If the driver does not load automatically, we have supplied a link above.
Winner of Flow Control's 2013 Innovation Award!
The votes are in! The Fox Model FT3 Thermal Mass Flowmeter and Temperature Transmitter has won the Flow Control 2013 Innovation Awards. The innovative Calibration Validation feature, using the CAL-V and Zero CAL-CHECK® tests, has paved the way for this advanced meter to garner the votes necessary to win this honor. Fox is very pleased and would like to thank all who have voted for this outstanding product.
Read the Digital Issue of Flow Control’s Announcement...
Winner of Processing’s Breakthrough Products of the Year Award!
Processing Magazine has awarded Fox Thermal’s Model FT3 Thermal Mass Flowmeter & Temperature Transmitter the Breakthrough Products of the Year award for 2012. These awards recognize products, technologies and services that made significant contributions in the process industries within the last year and are expected to impact the industry for years to come.
Read the article describing Calibration Validation feature of the Model FT3.
The Fox Thermal Model FT3, a multiple award-winning thermal gas mass flow meter manufactured in the United States by Fox Thermal.
The Model FT3 was designed with our oil and gas customers in mind. This meter is Quad O (OOOO) compliant and is perfect for use in flare gas applications along with other fuel gas measurement.
The Model FT3 measures gas flow rate in standard units (SCFM, NM³/hr, LBS/HR, KG/HR & many more) without the need for temperature and pressure compensation.
FT3 View™ - a free software tool –- allows the user to connect to and configure the FT3 using USB to a PC or laptop.
For complete specs please see the Fox Thermal Model FT3 Flow Meter Datasheet.
This site uses cookies, Learn More. Accept Cookies Reject Cookies
Copyright © 2023
Fox Thermal | 399 Reservation Rd. | Marina, CA 93933 | (831) 384-4300 | www.foxthermal.com
Fox Thermal (“Fox Thermal”, “we”, “us”) is committed to protecting and respecting your privacy. We adhere to the Privacy Policy together with any disclaimers regarding any personal data (“Data”) we collect from you, that you provide to us, or that is provided to us relating to you. Please read the following carefully to understand our use of personal Data.
Data We May Collect from You
We collect personal data from you, which you volunteer when you provide such Data to us via our services with which you interact. These services include, but are not limited to, the Fox Thermal website, personal meetings, conference and trade show attendance, referrals from our representatives, distributors and/or other customers, etc. The Data we may collect includes, but is not limited to, your full name, your business or personal address, your various email addresses, your various phone numbers, your company, details of your relationships with our representatives and/or distributors, and any other Data that we feel is legitimately necessary for us to conduct normal business operations with you.
When you access our website, your device’s browser provides us with information such as your IP address, browser type, access time and referring URL. This Data is collected and used to compile statistical data and may be used to help us improve our website and the services and products we offer to you.
Cookies
This website uses “cookie” technology. A cookie is a piece of code stored by the browser on your computer at the request of our server. We may use cookies to deliver content specific to your interests and to save your personal preferences so you do not have to re-enter them each time you connect to our website. Our cookies are not available to other websites. Our cookies will record the following: your IP gateway address, the point of entry to the site, search terms used, your navigation through the site and other information that helps us make the site more accessible. You are always free to decline our cookies, if your browser permits, or to ask your browser to indicate when a cookie is being sent. You can also delete cookie files from your computer at your discretion. Note that if you decline our cookies or ask for notification each time a cookie is being sent, this may affect your ease of use of this website.
Links to Other Sites
Our website may, from time to time, contain links to and from other websites. If you follow a link to any of those websites, please note that those websites have their own privacy policies and that we do not accept any responsibility or liability for those policies. Please check those policies before you submit any data to those websites.
How Fox Thermal Shares Data
Fox Thermal may share Data with its independent sales representatives, your local independent sales representative, Fox Thermal’s distributors, Fox Thermal’s other brands, or a third-party email service which Fox Thermal would hire strictly as a conduit to send out informational or marketing emails which Fox Thermal creates. Fox Thermal does not and will not sell Data, nor do we authorize any third party to use your personal for their own purposes unrelated to Fox Thermal’s legitimate business purposes.
Fox Thermal may use your personal Data:
Security and Length of Stored Data
Fox Thermal is committed to protecting the security of your personal Data. We use a variety of security technologies and procedures to help protect your personal Data from unauthorized access and use. As effective as modern security practices are, no physical or electronic security system is entirely secure. We cannot guarantee the complete security of our databases, nor can we guarantee that information you supply will not be intercepted while being transmitted to us over the Internet. We will continue to revise policies and implement additional security features as new technologies become available.
The Data we collect will be stored as long as is necessary to do legitimate business with you.
As the Data Subject, You Have the Right to:
How Can You Contact Fox Thermal Regarding this Policy?
All questions, comments, requests and complaints regarding this Policy and the information we hold are welcome and should be addressed to us at it@foxthermal.com or in writing at:
Changes to this Policy
Fox Thermal reserves the right to make changes to this Policy at our sole discretion and without prior notice. If we make changes, we will post them here. By continuing to use this site or our other services, or otherwise continue to provide Data after we post such changes, you accept and agree to this Policy as modified.
If you are interested in linking, quoting, or reprinting information from Fox Thermal in whole or in part, please read our Fox Thermal copyright policy:
Linking to Fox Thermal Website
You are welcome to use short quotes from Fox Thermal in your website or blog as long as proper credit is given. Always Contact Fox Thermal before linking to the Fox Thermal website unless prior permission is given.
Reprint Permission
If you are interested in reprinting any of the content from Fox Thermal on your website, blog or in your publication, please contact Fox with your request. Information from Fox Thermal can be reprinted only after permission is given. You may not republish an entire Fox Thermal post without approval.
Print Media
You must print the full Internet address or document title (with Fox Thermal company name) where you received the information within your publication.
IP Addresses:
An IP address is a number that is assigned to your computer or network when you are on the Internet. When visitors request pages from our Web Site, our servers log the visitor's IP address. We may collect IP addresses for a variety of internal purposes, such as system administration, to report aggregate information to our business partners or to audit the number of visits to different pages on our Web Site. Please note that some services within our Web Site, such as certain message boards, may display IP addresses along with the message poster's name and message.
Copyright Violation and Misuse
If we discover a website, blog or published material using our website or literature content illegally, we will file a formal complaint.