PLEASE TURN YOUR DEVICE TO LANDSCAPE ORIENTATION.

All Fox Products

METER TYPE /
LINE SIZE
Insertion: 1.5" - 70"
Insertion: 1.5" - 70"
Inline (w/flow conditioners): ¼" - 6"
Remote sensor mounting optional
Insertion: 1.5" - 70"
Inline (w/flow conditioners): ¼" - 6"
Remote sensor mounting optional
Insertion: 1.5" - 70"
OUTPUTS
USB Port;
4-20mA;
Selection of one 2nd output:
  • Pulse
  • Communication Options
USB Port;
2 X 4-20mA;
Pulse;
Communication Options
USB Port;
2 X 4-20mA;
Pulse;
Communication Options
USB Port;
4-20mA;
Selection of one 2nd output:
  • Pulse
  • Communication Options
COMMUNICATION OPTIONS
RS485 Modbus RTU;
BACnet MS/TP; HART
RS485 Modbus RTU;
BACnet MS/TP;
Profibus-DP;
DeviceNet;
Ethernet Modbus TCP
RS485 Modbus RTU;
HART
RS485 Modbus RTU;
HART
CONTACT OR DISCRETE I/O
Discrete output for alarms*
Discrete output for alarms*
Contact input to reset total
Discrete output for alarms*
Contact input to reset total
Discrete output for alarms*
DATALOGGER
None
None
Optional; with date/time stamp
None
CALIBRATION VALIDATION (in-situ verification)
Zero CAL-CHECK®
None
CAL-V™
Zero CAL-CHECK®
CAL-V™
POWER
10-30VDC**
24VDC ±10%
85-264VAC***
24VDC ±10%
85-264VAC***
10-30VDC**
DISPLAY
(Optional)
2-Lines x 16 characters
Backlit
(Standard)
2-Lines x 16 characters
Backlit
(Optional)
2-Lines x 16 characters
Backlit
Infrared buttons
(Optional)
2-Lines x 16 characters
Backlit
GAS SELECT MENU
Yes - Gas-SelectX®
None
None
Yes - Expanded Gas-SelectX®
GAS/GAS MIXES
Air
Argon
Butane
Carbon Dioxide
Helium
Click here for more gas options****
Dry pure gases,
Gas mixes (gas composition analysis must be submitted for factory calibration)
Dry pure gases,
Gas mixes (gas composition analysis must be submitted for factory calibration)
Air
Argon
Butane
Carbon Dioxide
Helium
Click here for more gas options
SENSOR
DDC-Sensor™
¾" probe
PowerPro™ Sensor
½" probe
PowerPro™ Sensor
½" probe
2nd Gen DDC-Sensor™
¾" probe
FREE SOFTWARE DOWNLOADS
Yes - FT1 View™
Yes - FT2A View™
Yes - FT3 View™
Yes - FT4A View™
ACCURACY
±1% R ±0.5% FS (air)
±1.5% R ±0.5% FS (all other gases)
±1% R ±0.2% FS
±1% R ±0.2% FS
±1% R ±0.5% FS (air)
±1.5% R ±0.5% FS (all other gases)
VELOCITY RANGE
0 - 15,000 SFPM;
0 - 71 NMPS
0 - 60,000 SFPM;
0 - 283 NMPS
0 - 60,000 SFPM;
0 - 283 NMPS
0 - 60,000 SFPM;
0 - 283NMPS
SENSOR TEMPERATURE RATINGS
-40° to 250°F (-40° to 121°C)
ST: -40° to 250°F (-40° to 121°C)
HT: -40° to 650°F (-40° to 343°C)
ST: -40° to 250°F (-40° to 121°C)
HT: -40° to 650°F (-40° to 343°C)
-40° to 250°F (-40° to 121°C)
MAXIMUM PRESSURE
300 psig (20 barg)
500 psig (34 barg)
500 psig (34 barg)
500 psig (34 barg)
APPROVALS
CE Mark*****
FM/FMc Class I Div 1*****
ATEX/IECEx Zone 1*****
CE Mark*****
FM/FMc Class I Div 2*****
CE Mark*****
FM/FMc Class I Div 1*****
ATEX/IECEx Zone 1*****
CE Mark*****
FM/FMc Class I Div 1*****
ATEX/IECEx Zone 1*****
BLM/API Pending
*Contact output in place of pulse
**12 - 28VDC for CE Mark approvals
***100 - 240VAC for CE Mark approvals
****Gas mix can contain any three of the gases listed for the FT1 in any proportion totaling 100%
*****See Model Datasheets for more specific information on Approvals

Copyright © 2017